Zigbang SHP-H60F - Automatic/manual lock setting guide

Automatic/Manual Locking Setting


The Automatic Locking mode activates the automatic locking function of the door when it is closed.


Open the battery cover of the inner body. Set the [Automatic/Manual Locking] toggle switch of the inner body to A (automatic) or M (manual) position.


Automatic: The door is automatically locked 1 second after the door is closed. If the batteries are completely discharged, the door may not be locked.


Manual: The door does not automatically lock when it is closed. It is locked when you press [CLOSE] on the inner body or touch the [number pad] on the outer body.


Note: ● Regardless of the automatic/manual locking setting, the door is automatically locked 7 seconds after the door is not opened after the door locking is not opened.


Volume Setting


The sound that is generated when the number buttons are touched, when the door is locked, or when the locked door is unlocked, can be set according to the user’s preference. The product is initially set to generate the operation sound of the door lock. (Level 1)


Open the battery cover of the inner body. Set the [Volume] switch to [0]~[2].


- [0]: The sounds of door opening/closing and key touching are deactivated (except an alarm sound). 

- [1]~[2]: All sounds are activated, and the sounds get louder as the step becomes higher.


Security Assurance Mode Activation/Deactivation


This mode is to prevent opening the door from outside while someone is inside.


Security Assurance Mode Activation

While the door is locked, press the [CLOSE] button for 3 seconds.


Security Assurance Mode Deactivation

Pull the handle of the inner body down, or turn the manual locking switch left or right to cancel the Security Assurance Mode Setting.