Double Authorisation Mode
Double authorisation mode requires both password and key tag to open the door, ensuring more security. To set the double authorisation mode, one or more key tags need to be registered. When purchased, the door lock is not set to double authorisation mode initially.
1. Enter Setting Mode Select the Setting mode. (Refer to the Setting mode)
2. Select Double Authorization Mode
Touch the [3] button.
Touch the [*] button.
3.1 Select Double Authorization Setting
Touch the [1] button.
Touch the [*] button.
3.2 Cancel Double Authorization
Touch the [3] button.
Touch the [*] button.
Door Lock Time Setup Function
This function sets the time interval between the moment the door open/close sensor recognizes the door as closed and the moment the deadbolt locks the door. In an environment that the door closes slowly and the deadbolt jams before the door is fully closed, the situation can be fixed by adjusting the door lock time. By default, the door lock time is set to 1 second.
1. Enter Setting Mode Select the Setting mode. (Refer to the Setting mode)
2. Select Door Lock Time Setting Mode
Touch the [4] button.
Touch the [*] button.
3. Set Time (Second)Touch the [1]~[9] buttons.
Touch the [*] button.